Total Energy Power Meter LED Pulse Senson Count electricity cons View larger

Total Energy Power Meter LED Pulse Senson Electricity Consumption

Immediately Available

52.90EUR tax incl.

CODE 0100

The Go Green Total consumption meter is only suitable for modern electricity meters with LED pulse.
Go Green Total energy meter
Implementation:
The Go Green Total consumption meter will help you save on your electricity consumption and at the same time make a contribution to reducing CO2 emissions. You should note that the total consumption meter is only a means to the real savings you realize yourself. If the values ​​on the display as low as possible, you save one on your energy bills and reduce CO2 emissions.

This set contains the following parts:
A. Sensor

B. Port plugs and extension cords

C. Installation flat plate
D. installation plate round
   
Assembly and installation of batteries
Remove the battery cover and insert the two AA batteries. Insert the batteries with the correct polarity as indicated in the battery compartment. After inserting the batteries, all functions on the display will light up briefly.
If all the batteries are almost empty in the counter, a small battery icon will appear on the display. We advise to replace the batteries to you as soon as possible.
By means of a relief on the back, you can choose the counter set by a screw or by means of an extensible base on a flat surface.
Positioning of the sensor
The Go Green Total consumption meter is only suitable for modern electricity meters with LED pulse.
This is a small light that indicates how much energy you consume. Depending of the type of electricity meter is the 1,000 - 10,000 blinks per kilowatt hour (kWh)Before removing the belt, check the correct Installation disk (C) or (D). It is important that the LED is located precisely in the middle of the opening of the installation plate. Remove the tape and attach the installation plate on the blade. Place the sensor gently in the eye of the installation plate and rotate the sensor clockwise until you feel a "CLICK". The sensor has now been attached to the installation plate.

Connect the end of the sensor with the cable of the utility meter.
WARNING
Avoid direct light falls on the sensor when it is connected. This can lead to errors on the screen.
Setup
To activate the setup menu, press for 3 seconds, the alarm on / off / Menu button:

 Display shows   -       Instalation

12/24 Hours  -  The "+" and "-" keys to adjust - Using the SET / ALARM key to confirm

Hour  -  The "+" and "-" keys to adjust - Using the SET / ALARM key to confirm

Minutes  -  The "+" and "-" keys to adjust - Using the SET / ALARM key to confirm

Month/Day or Day/Month  -  The "+" and "-" keys to adjust - Using the SET / ALARM key to confirm

Year  -  The "+" and "-" keys to adjust - Using the SET / ALARM key to confirm

Day  -  The "+" and "-" keys to adjust - Using the SET / ALARM key to confirm

Month  -  The "+" and "-" keys to adjust - Using the SET / ALARM key to confirm

Imp (pulse) -  Set the number of pulses that delivers your electricity meter per kilowatt hour (kWh). This information is on your electricity meter. 1000 pulses / kWh are standard.   -  The "+" and "-" keys to adjust - Using the SET / ALARM key to confirm

CO2 Set on 0,44. This is Standard for Europa   -  The "+" and "-" keys to adjust - Using the SET / ALARM key to confirm

Electricity price per kWh - See you on your energy bill you have to pay per kWh including supervening costs. Or call your local power company.
See you on your energy bill you have to pay per kWh including supervening costs. Or call your local power company. The "+" and "-" keys to adjust - Using the SET / ALARM key to confirm

Alarm settings

If your usage is above a preset value, it is possible to display a warning about your energy consumption.

Select using the "CLEAR HISTORY MEM" button which period you want to select.

 

Use the "COST, CO2, kWh" button on the warning wish (price, CO2 or kW) Select using the "" or "-." Button and confirm the value of using the "SET / ALARM "button.

example
I would like a warning with a consumption of more than 5 kW in 1 hour. Press the "SET / ALARM" button. Select "Hour" with the help of the "HISTORY CLEAR MEM" button. Select "kWh" using the "COST, CO2, kWh" button. Press the "SET / ALARM" button and select 0005.00
The alarm is now set and is activated by the "ALARM ON / OFF" button. As a sign that the alarm has been set, a small clip will appear in the display.

Tariff setting
It is possible to set different rates during the day and one times. This is only necessary if you want to apply different tariffs per day. Example:

Between 06:00 to 18:00, your electricity price 1.65
Between 18:00 - 24:00 is your electricity price 1.75
From 24:00 - 06:00 is your Electricity Price 1:35

To adjust the various rates, press for 3 seconds the "COST, CO2, kWh" button. The top display for T1 tariff appear first Set the right price using the "" and "-" buttons. Confirm with "SET / ALARM" button and set the start time of T1. Repeat to set the T2 and T3 above steps. You can insert up to 3 tariffs. The applied tariff number will appear on the display.

Display
The upper part of the screen shows you the latest information about your usage and the center of the historical information. By means of the "COST, CO2, kWh" button you can switch between information regarding the CO2 consumption, switch costs in euros and consumption in kWh. Using the "CLEAR HISTORY MEM" button you can select information based on hour, day, week and month. The "+" s "-" buttons to select in the past. If you need information from a day ago, then press the "-" key (- 1 appears in the display).
Clearing Memory
Press for 3 seconds "HISTORY CLEAR MEM" button until you hear a signal. All historical data are now cleared.

SAFETY
This product is manufactured to give you years information, if you treat it with caution. Here are a few safety rules:

First The product does not immerse in water.
Second Not clean the product with eating or abrasive materials. Which may cause scratches on the surface and damage the internal circuit.
Third Do not expose this product to extreme violence, shaking, dust, high temperature and humidity. This can lead to poor functioning, shortening the life of parts, damage to the battery and other parts.
4th Internal parts do not touch. Void your warranty and may cause unnecessary damage. The internal parts are maintenance.
5th Only use new batteries. Not mix old and new batteries.
6th Read these instructions carefully before use.

Specifications:
Power: 2 x AAA 1.5 volt battery
Battery Life:> 1 year

 
Thanks for Visiting www.MarketNet.gr